Filters A and B have the same settings.
Filter A or B:
Selects the frequency range of the digital filter to be used.
mS:
Defines the signal integration time in milliseconds for filter A or B. The default number
of milliseconds is the reciprocal of the center frequency. A multiple of this number will give
the best response.
uV:
Defines the micro volt level of the threshold.
Threshold Button:
Controls how the threshold will be used. If "+" is displayed the condition
specified is that the signal must be above
the uV threshold. . If "-" is displayed the condition
specified is that the signal must be below
the uV threshold. If "0" is displayed the threshold
condition is turned off for that filter band.
Range uV: specifies the range of uVolts from filter A that will be mapped to the MIDI,
General Graph, ASCII and/or DDE output if the conditions specified are satisfied.